HIOKI 3284 Clamp meter (AC 200A)
制造商: HIOKI Model: 3284 - 报价要求
- 联系
AC Current range: AC (RMS or Peak value)20.00 or 200.0 A AC, 2 ranges (±1.3 % rdg. ±3 dgt. at 50 or 60Hz), AC+DC (RMS or Peak value)20.00 or 200.0 A AC, 2 ranges (±1.3 % rdg. ±13 dgt. at 50 or 60Hz), Effective value rectifier
DC Current range: DC (Average or Peak value)20.00 or 200.0 A DC, 2 ranges (±1.3 % rdg. ±3 dgt.)
AC Voltage range: AC (RMS or Peak value)30.00 to 600 V AC, 3 ranges (±1.0 % rdg. ±3 dgt. at 50 or 60Hz), AC+DC (RMS or Peak value)30.00 to 600 V AC, 3 ranges (±1.0 % rdg. ±7 dgt. at 50 or 60Hz), Effective value rectifier
DC Voltage range: DC (Average or Peak value)30.00 to 600 VDC, 3 ranges (±1.0 % rdg. ±3 dgt.)
Frequency Measurement: 10 to 1000 Hz, 2 ranges (±0.3 % rdg. ±1 dgt.)
Frequency characteristics (at AC current / voltage): DC, 10 to 2 kHz
Max. Circuit Voltage: 600 V AC rms (insulated wire)
Power Supply: 6F22(006P) × 1, Continuous use 25 hours, or AC adapter
Core jaw dia.: Ø33 mm(1.3 in)
Dimensions: 62 mm(2.44 in)W × 230 mm(9.06 in)H × 39 mm(1.54 in)D
Weight: 460 g (16.2 oz)
Accessories: 9207-10 TEST LEAD (1), 9399 CARRYING CASE (1), Hand strap (1)
AC Current range: | AC (RMS or Peak value)20.00 or 200.0 A AC, 2 ranges (±1.3 % rdg. ±3 dgt. at 50 or 60Hz), AC+DC (RMS or Peak value)20.00 or 200.0 A AC, 2 ranges (±1.3 % rdg. ±13 dgt. at 50 or 60Hz), Effective value rectifier |
DC Current range: | DC (Average or Peak value)20.00 or 200.0 A DC, 2 ranges (±1.3 % rdg. ±3 dgt.) |
AC Voltage range: | AC (RMS or Peak value)30.00 to 600 V AC, 3 ranges (±1.0 % rdg. ±3 dgt. at 50 or 60Hz), AC+DC (RMS or Peak value)30.00 to 600 V AC, 3 ranges (±1.0 % rdg. ±7 dgt. at 50 or 60Hz), Effective value rectifier |
DC Voltage range: | DC (Average or Peak value)30.00 to 600 VDC, 3 ranges (±1.0 % rdg. ±3 dgt.) |
Frequency Measurement: | 10 to 1000 Hz, 2 ranges (±0.3 % rdg. ±1 dgt.) |
Analog Output: | None |
Frequency characteristics (at AC current / voltage): | DC, 10 to 2 kHz |
Display Section: | Current / 2500 dgt. Voltage / 3750 dgt. Bar graph / 35 seg |
Sampling Rate: | 2 or 4 times/sec (Slow: 1 times/3 sec) |
Crest Factor (RMS): | 2.5 (1.7 at 200 A range), 1.5 (200 A range) |
Max. Circuit Voltage: | 600 V AC rms (insulated wire) |
Power Supply: | 6F22(006P) × 1, Continuous use 25 hours, or AC adapter |
Core jaw dia.: | Ø33 mm(1.3 in) |
Dimensions: | 62 mm(2.44 in)W × 230 mm(9.06 in)H × 39 mm(1.54 in)D |
Weight: | 460 g (16.2 oz) |
Accessories: | 9207-10 TEST LEAD (1), 9399 CARRYING CASE (1), Hand strap (1) |
- 质量承诺
- 正品保修
- 送货到家
- 交易简单化